Omron HEM7130 Deluxe BP Monitor + MC245

Omron HEM7130 Deluxe BP Monitor + MC245
$130.49
$130.49 about 6 years ago

  Information 5 Year Warranty (Aus/NZ) General Information The Omron HEM7130 Deluxe Upper-Arm Blood Pressure Monitor is easy to use and features 60 reading memory with date & time and also irregular heartbeat, body movement and blood pressure level indicators.*Bonus Omron MC245 Digital Thermometer!• Easy to Use One-Touch Operation• Intellisense TechnologyAutomatically applies the right amount of pressure for fast, accurate and more comfortable measurements• 60 Reading Memory with Date & Time60 memory storage allows you to review the last 60 readings with a touch of a button• Soft Cuff (Med-Lge)22-42cm arm circumference • Cuff Wrapping GuideIndicator confirms the cuff has been wrapped correctly on the user's arm• Irregular Heartbeat IndicatorThis monitor can detect an irregular heartbeat (arrhythmia) which can assist with early diagnosis*. If an irregular heartbeat is detected, an indicator icon will appear alerting the user to consult with a medical professional. *N.B. Only a doctor can diagnose arrhythmia • Body Movement IndicatorAlerts user if anybody movement has occurred during the blood pressure reading• Blood Pressure Level IndicatorAlerts you if your blood pressure reading exceeds internationally recognised guidelines for normal home blood pressure levels• Advanced Averaging FunctionExclusive technology automatically displays the average of up to the last 3 readings taken within the last 10 minutes• LCD Display • Powered by 4 x AA BatteriesOptional extra: AC adaptorBlood Pressure MonitorFor people with high blood pressure. Consult your doctor to evaluate the readings. Check your device periodically for accuracy.ThermometerYour healthcare professional will advise you whether this product is suitable for you/ your condition. Always read the label and instructions. Use only as directed. If symptoms persist see your healthcare professional. Miscellaneous Drug Interactions Warnings Please see instruction manual for full list of warnings.Blood Pressure Monitor• Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, pregnancy, pre-eclampsia, masectomy, renal disease or severe blood flow problems or blood disorders as cuff inflation can cause bruising• Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous• Do not adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High / Low Blood Pressure• The monitor is not intended to be a diagnostic device• Do not use the unit for any purpose other than measuring blood pressure• Do not use the device on the injured arm or the arm under medical treatment• Do not wrap the arm cuff on the arm while being on an intravenous drip or blood transfusion• Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt• Do not apply or inflate the arm cuff around any body parts other than your upper arm• Do not take measurements more than necessary. It may cause bruising due to blood flow interference• Remove the arm cuff if it does not start deflating during the measurement• The air tube or the AC adapter cable may cause accidental strangulation in infants• Keep out of reach of children. Contains small parts that may cause a choking hazard if swallowed• If there are any abnormalities during the measurement, remove the arm cuff• Do not use this device on infants, children or persons who cannot express themselves• Do not inflate the arm cuff more than necessary• Stop using this monitor and consult your doctor if you experience skin irritation or discomfort• Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results• Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit• Do not use the device with other medical electrical (ME) equipment simultaneously• Do not use this monitor in areas containing high frequency (HF) surgical equipment, magnetic resonance imaging (MRI) equipment, computerized tomography (CT) scanners or in oxygen rich environments• Follow the battery/ AC adaptor instructions carefullyThermometerWARNING - KEEP BATTERIES OUT OF REACH OF CHILDREN • Swallowing may lead to serious injury in as little as 2 hours or death, due to chemical burns and potential perforation of the oesophagus• If you suspect your child has swallowed or inserted a button battery immediately call the 24-hour Poisons Information Centre on 13 11 26 (Australia) or 0800 764 766 (New Zealand) for fast, expert advice• Examine devices and make sure the battery compartment is correctly secured, e.g. that the screw or other mechanical fastener is tightened. Do not use if compartment is not secure• Dispose of used button batteries immediately and safely. Flat batteries can still be dangerous• Tell others about the risk associated with button batteries and how to keep their children safe• A high or prolonged fever requires medical attention, especially for young children. Please contact your doctor• Conducting self-diagnosis based on the measurement results and/or treatment can be dangerous. Please follow the instructions of your doctor. Self-diagnosis may worsen the symptoms• Do not use the thermometer to measure anything other than human body temperatures• This thermometer is used for taking temperatures through oral, rectal or underarm. Do not attempt to take temperatures at other sites, such as in the ear, as it may result in false readings and may lead to injury• Keep out of reach of children. Contains small parts that may cause a choking hazard if swallowed• Do not allow children to take their temperatures unattended. Children may injure themselves when attempting to take temperatures without supervision• Do not attempt rectal measurements on persons with rectal disorders. Doing so may aggravate or worsen the disorder• Do not force the thermometer into the rectum. It is recommended to lubricate with a water-soluble gel. Stop insertion and abort the measurement when pain is present. Failure to do so may lead to injury• Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit• Follow the battery instructions carefully Common Uses Ingredients Cuff- LATEX FREE Directions Please see instruction manual for detailed instructions.Blood Pressure Monitor• Avoid bathing, drinking alcohol/caffeine, smoking, exercising and eating for 30 minutes before taking a measurement• Rest for at least 5 minutes before taking the measurement• Sit upright on a chair with your legs uncrossed and feet flat on the floor, with your back and arm being supported• Remove tight-fitting clothing from your arm. Do not roll up a tight sleeve. Do not place the arm cuff over thick clothes• Wrap the arm cuff firmly in place around the left upper arm. Please see instruction manual if needing to use the right arm.• The bottom edge of the arm cuff should be 1 to 2 cm above your elbow• The air tube should be on the inside of your arm and aligned with your middle finger• Rest your arm on a table so that the arm cuff is at the same level as your heart• Ensure solid connection of the airplug and cuff to main unit• Ensure you remain still and do not talk during the measurement• Press the START/STOP button• The cuff will inflate and a result will display on the screen (approx. 30-60 secs)• The reading will be automatically saved in the memoryThermometer• Press the on/off button• Apply the thermometer to the measurement site (oral/rectal/underarm)• When the reading is ready, the thermometer will emit a beep sound 3 times. Remove thethermometer from the measurement site and read the result Indications