Shelly Pro 3EM-3CT63 (SH-SHELLY3EMP3CT)

Shelly Pro 3EM-3CT63 (SH-SHELLY3EMP3CT)

Price$215

In stock at Umart

Price checked today

Buy at Umart

We may earn a commission if you buy; it doesn't change your price. Check the price at Umart before you buy. How we make money

Price history

Tracking since today

The price hasn't changed since we started tracking it. We'll show its history once it does.

About this product

Brand
Shelly
Store
Umart
Category
Home & Garden > Business & Home Security > Motion Sensors
SKU
95828

NOTE: This device does not have a built-in relay. Contactor control is provided using a Shelly Pro Addon attached to the Shelly Pro 3EM-3CT63.

SPECIFICATIONS:

PHYSICAL
Size (HxWxD) Shelly Pro 3EM-3CT63: 94x19x69 mm / 3.70x0.75x2.71 in
Shelly 3CT63: 14x54x26 mm / 0.55x2.12x1.02 in
Weight Shelly Pro 3EM-3CT63: 62 g / 2.19 oz
Shelly 3CT63: 32 g /1.12 oz
Screw terminals max torque 0.4 Nm / 3.5 lbin
Conductor cross section Shelly Pro 3EM-3CT63: 0.5 to 2.5 mm² / 20 to 14 AWG
Shelly 3CT63: 0.2 to 2.5 mm² / 24 to 14 AWG (solid, stranded, and bootlace ferrules)
Conductor stripped length 6 to 7 mm / 0.24 to 0.28 in
Mounting Shelly Pro 3EM-3CT63: DIN rail
Shelly 3CT63: Freestanding on phase wires
Conductor aperture Shelly 3CT63 Ø9 mm / Ø0.35 in
Shell material Plastic
Shell color White
ENVIRONMENTAL
Ambient working temperature -20°C to 40°C / -5°F to 105°F
Humidity 30% to 70% RH
Max. altitude 2000 m / 6562 ft
ELECTRICAL
Power supply 100-260 V~ 50/60 Hz
Power consumption < 3 W
External protection Tripping characteristic B or C,
16A max. rated current,
min. 6 kA interrupting rating,
energy limiting class 3
Shelly 3CT63 electrical strength 1000 V~, 60 sec
SENSORS, METERS
Internal-temperature sensor Yes
Voltmeter (AC) 100 - 260 V
Voltmeter accuracy ±1 %
Ammeter (AC) 0 - 63 A
Ammeter accuracy ±1 % (2 - 63 A), ±2 % (1 - 2 A), ±5 % (0 - 1 A)
Compatible current transformers 3CT63
Power and energy meters Active and apparent power
Active and apparent energy
Power factor
Fundamental active and fundamental reactive energy
Channel-to-channel calibration minimum load 500 W per channel
No load threshold 30 VA per channel
Measurement data storage At least 60 days of 1 min data resolution
Data export CSV for PQ recorded values
JSON format export through RPC
RADIO
WI-FI
Protocol 802.11 b/g/n
RF band 2400 - 2495 МHz
Max. RF power < 20 dBm
Range Up to 30 m / 100 ft indoors and 50 m / 160 ft outdoors
(Depends on local conditions)
BLUETOOTH
Protocol 4.2
RF band 2400 - 2483.5 MHz
Max. RF power < 4 dBm
Range Up to 10 m / 33 ft indoors and 30 m / 100 ft outdoors
(Depends on local conditions)
MICROCONTROLLER UNIT
CPU ESP32-D0WDQ6
Flash 16 MB
FIRMWARE CAPABILITIES
Webhooks (URL actions) 20 with 5 URLs per hook
Scripting Yes
MQTT Yes
Scripting Yes
Encryption Yes